General Considerations and Limitations

 Release Notes Contents

Home

General Considerations and Limitations

Important Cautions

Where to find product documentation and other information

 

Search NOW Forums
• NOW Forums
 Provide Feedback
• doccomments
 NOW Knowledge Base and Technical Documentation
•  Technical Documentation
•  Submit New Knowledge

This section describes general considerations and known limitations, including:

Do not enable diagnostics on the console

During routine operation, do not issue the CLI command diag enable from the console. Diagnostic output sent to the console can sometimes interfere with operations such as disk shelf firmware upgrades. If diagnostics are enabled, you can disable them with the CLI command diag disable.

Repeatedly issuing the CLI command shelffirmware status from the console can cause VTL crash

Repeatedly issuing the CLI command shelffirmware status from the console might trigger an assertion and crash of the VTL. If this happens, reboot the VTL. The problem does not cause any form of data loss or corruption. The problem does not occur if you are issuing CLI commands from, for example, an ssh session.

Kernel panic during shelf firmware upgrade when there is I/O activity

On a VTL system that is undergoing a shelf firmware upgrade, any type of I/O
activity may cause a kernel panic. This applies to any type of I/O activity
such as frontend reads and writes and backend exports and clones.

There should be absolutely no I/O activity while a VTL system is undergoing a shelf firmware upgrade. Additionally, diagnostics must be disabled on the VTL console with the command diag disable, if the console is connected.

If this kernel panic does happen, reboot the VTL. This kernel panic does not result in data loss or corruption.

Appliance stops instead of rebooting after firmware upgrade

After a firmware upgrade, you are prompted to reboot the VTL appliance. Sometimes instead of rebooting after the firmware upgrade, the appliance stops responding. If this happens, power cycle the appliance. After the VTL is power-cycled, it boots with the new firmware version.

Cannot downgrade disk or shelf firmware

Do not install an earlier release of disk or shelf firmware than is already installed on the disk or shelf.

Operational restrictions while upgrading firmware

Make sure there are no backup, restore, import, export, or clone operations in progress during a disk or disk shelf firmware upgrade. Do not reboot or power cycle a VTL, or disk shelves, during a disk or disk shelf firmware upgrade.

Maximum number of slots per library

The recommended maximum number of slots per library is 1024.
This limit is not enforced, but it becomes difficult to use the GUI for some tasks when this limit is exceeded. The maximum supported number of slots per appliance is 10,000.

Some restrictions on drive/application/server combinations

Some combinations of otherwise supported tape devices, backup applications and backup servers are not currently supported. The not supported combinations include the following:

  • STK10000 tape drives, NetBackup, and Windows platforms
  • DTL-S4 tape drives, NetBackup, and Suse Linux platforms
  • IBM 3592 tape drives, NetWorker, and Solaris platforms
  • IBM 3592 tape drives, TSM, and Windows platforms
  • IBM 3592 tape drives, NetVault, and Suse Linux platforms

The combination of IBM 3592 tape drives, TSM, and AIX platforms is supported, but with this combination TSM sometimes displays incorrect reports of IO errors.

Check the NearStore VTL Compatibility List for supported tape drives, applications and backup servers.

VTL300/700/1400 appliance notes and limitations

Note the following features and limitations of the VTL300/700/1400 appliances:

  • All VTL300/700/1400 Fibre Channel ports support 4 Gbps, although the disk shelves restrict back-end port performance to 2 Gbps.
  • VTL300 appliances support a maximum of five shelves and two front-end ports.
  • VTL300 appliances require an optional HBA, if you want to connect the appliance to a tape device. The optional HBA provides two tape ports.
  • For improved performance, VTL700/1400 appliances support an optional, second hardware compression card (installed in slot 4).
  • For VTL700 appliances, if you are attaching more than 12 shelves, you must add to the basic configuration an additional HBA (installed in slot 3) for disks.
  • If you have a basic VTL700/1400 appliance, and need additional back-end ports (for example to attach a tape device) you can do these things:
    • Configure port 0d as a back-end port using the GUI task Configuration Tasks > Advanced > Options.
    • Add an additional HBA to slot 3 and add four back-end ports.
    • Add an additional HBA to slot 4 and add four back-end ports. Note that PCI slot 4 can also be used for the optional additional hardware compression card, so you can add one or the other, but not both.
  • Parallel SCSI is not supported on these platforms, although you can connect parallel SCSI tape devices by using a SCSI-to-Fibre Channel bridge.

VTL600/1200 appliance note

All of the virtual drive types supplied with VTL 5.2.3 allocate disk space assuming disk compression is used. Libraries defined before upgrading to VTL 5.2.3 are not affected by an upgrade to VTL 5.2.3, but if you install VTL 5.2.3, have software disk compression disabled, and you delete the entire VTL configuration, before building a new configuration, you must adjust the virtual drive types to allocate more disk space per virtual tape. For example, if your tape device compression ratio is 2:1, update the Disk Allocation Per Tape (GB) parameter on all virtual libraries to allocate twice the disk space as the physical tape capacity.

Action- and event- reporting can be excessive

Some error conditions, and some operating conditions, can generate multiple, repetitive messages, resulting in an excessive number of actions and events.

Removing all barcode ranges does not clear inventory listing

If you remove all barcode ranges from an ACSLS library, the inventory does not update.

After removing compression card, uncompressed writes are slow

If all compression cards are removed from a VTL appliance that previously had compression cards, uncompressed data writes might be slow. Once an appliance has used a compression card, the card is checked before all writes, so even uncompressed writes are delayed while waiting for the compression card to respond. Replacing the compression card restores normal performance.

Editing console input has some limitations

Some line editing functions, such as using up and down arrow keys to scroll through command line history, are not available when using the command line interface from the console, although available when using a session over ssh.

Admin cannot see customer-owned virtual tapes

If the customer option is enabled, a customer is created, and the customer creates some virtual libraries, an admin user will not be able to see those virtual libraries in the Virtual Tape List GUI screen.

Changes to licensing require a reboot

After adding or removing a license key, you need to reboot the appliance before the license becomes effective.

Although compression is enabled, imported virtual tapes do not use compression

When physical tapes are imported to a virtual library, the resulting virtual tapes are not compressed, even if compression is set on the virtual tape. If you overwrite the entire virtual tape, the new data is compressed.

Hardware compression card disappears

Occasionally after a reboot, one or more hardware compression cards might not be detected. If this happens, the system automatically attempts to clear the problem by rebooting once. If this does not clear the problem, an Action Required notification is issued and the system remains up.

SCSI Addresses screen data might be formatted incorrectly

If both port mapping and host access are enabled, and multiple ports are mapped to a device, the display on the SCSI Addresses screen for the second port and LUN might be formatted incorrectly. Rows after the first incorrectly formatted row might also be incorrectly formatted.

Disks with older firmware might become unresponsive after being plugged back in

Systems with 500 GB disks and versions of disk shelf firmware prior to AT-FCX version 32 might become unresponsive after the disks are unplugged and plugged back in. You might also observe many "I/O not completing" messages on the console.

You can prevent this problem by upgrading the disk shelf firmware on your NearStore VTL appliances. The NearStore VTL software version 5.2.3 package includes updated shelf firmware that you can install.

Unexpected I/O interruptions occur when creating more virtual devices

I/O might get interrupted from the virtual drives during the addition of a new virtual library or the expansion of an existing library. This is because the VTL sends out UNIT ATTENTION on all the LUNs to inform the initiator that the REPORT LUNS data has changed.

AutoSupport notification might fail during NearStore VTL startup

While a NearStore VTL appliance is starting up, conditions might occur that trigger an AutoSupport notification e-mail message, but if the network is not yet initialized, the attempt will fail. In such a case, the usual event action logging will occur on the appliance, but NetApp technical support will not receive notification.

A NearStore VTL might attempt to use a tape drive even after detecting a hardware failure in the drive

A NearStore VTL appliance might retry a failed physical tape drive, rather than redirect I/O to another available physical tape drive. If this occurs, disable the failed tape drive.

 

Legal Information